Patient Monitor 

Advanced Patient Monitor (10/12/15 inch )


Features

-The monitor adopts Ergonomic design and a compact structure to meet the needs of various parameter detections. It is suitable for adults, children, and newborns.

-Standard parameters: SpO2, 3/5 leads ECG, PR, HR, RESP, NIBP, 2*TEMP.

-Optional parameters: EtCO2, 12 leads ECG, 2*IBP.

-10/12/15 inch color LCD screen with optional touch screen and rotator knob.

-Capable to visualize 6 or more waveform. Support color coding for different waveform.

-28 ST segment analysis with ST trend with continuous display of ST value on screen.

-Multiple screen layout to view big font size in numeric and waveform.

-Trending facilities for up to 360 hours of both graphical & numerical along with event review facility for all parameters and full waveform disclosure facility.

-Different visual alarm with color coding and audible alarms for various parameters with three levels of

volume adjustment.

-Support HL7 protocol to access the central monitoring system, low-power design, extending battery life Configure, fanless design to ensure a quieter and cleaner environment Arrhythmia detection and analysis in various leads.

 

Product Performance

-Standard application: 5-leads ECG, NIBP, SpO2, RESP, TEMP, PR/HR

-Optional application: Touch screen, IBP, EtCO2 (mainstream/sidestream), 12-lead ECG, recorder, CMS

-Large font, dynamic short trend display interface, calculation of hemodynamics and cardiac output.

Specifications

Display

Size: 10 inches Color TFT LCD 12 inches Color TFT LCD 15 inches Color TFT LCD

Resolution: 1024*768 pixels  1366*768 pixels

 

ECG

3-lead: I, II, III

5-lead: I, II, III, aVR, aVL, aVF, V

ECG Range: 0~100%

ECG Resolution: 2.36uV/LSB

HR Range: 15~300bpm(adult), 15~250bpm(pediatric/neonate) HR Accuracy: ±1 bpm or ±1%, whichever is greater.

RR Range: 0~120bpm

RR Accuracy: 15~120rpm: ±2rpm or ±2% <15rpm: Undefined

Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s, less than ±5% error

Display sensitivity: 2.5 mm/mV (X0.25), 5 mm/mV (X0.5), 10 mm/mV (X1), 20 mm/mV (X2), 40 mm/mV (X4), Auto, less than ±5% error

 

SPO2

SPO2 Measurement Range: 0~100%

SPO2 Accuracy: 70 to 100%: ±2% (adult/pediatric, without motion)

70 to 100%: ±3% (neonate, without motion)

0 to 69%: Not specified.

PI Range: 0~20%

PR Range: 25-250bpm

PR Accuracy: ±2bpm or ±2% (whichever is greater)

 

TEMP

Technique: Thermal resistance

Measurement Range: 0~50.0Accuracy: ±0.2°C

Resolution: 0.1°C Refresh Rate: 1s

Alarm limit range: Temp High: (low limit +0.1) ~ 50.0

Temp Low: 0~ (high limit -0.1)

 

NIBP

Measure method: Automatic oscillation method Pressure Range: 0~300mmHg (0~40kPa)

Pressure Accuracy: ±2mmHg or ±1% of reading (whichever is greater) Resolution: 1mmHg or 0.1kPa

SYS Range: Adult: 40-270mmHg

Pediatric: 40-200mmHg Neonate: 40-130mmHg

DIA Range: Adult: 10-210mmHg

Pediatric: 10-162mmHg Neonate: 10-90mmHg

Mean Range: Adult: 20-230mmHg

Pediatric: 20-170mmHg Neonate: 20-100mmHg

Accuracy: mean deviation<±5mmHg, standard deviation<8mmHg Work pattern: manual, automatic, continuous measurement

Automatic mode measurement interval: 1min/ 2min/ 3min/ 4min/ 5min/ 10min/ 15min/ 30min/ 60min/ 90min/ 2h/ 3h

Continuous mode measurement time: 5 min Maximum single measurement time: 180s

 

Respiration

Technique: Trans-thoracic impedance Lead: Options are lead I and II

Respiration excitation waveform: 300µA RMS, 62.8kHz (±0%) Respiration impedance range: 0.3~5Ω

Baseline impedance range: 200~2500Ω (using an ECG cable with 1kΩ resistance) Bandwidth: 0.2~2Hz (-3 dB)

Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s

 

PR

Measurement range: 25bpm~250bpm Resolution: 1bpm

Alarm limit: PR High: (PR Low limit +1bpm) ~ 300bpm PR Low: 15bpm ~ (PR High limit -1bpm)

HR

Measurement range: 15~300bpm (adult

15~350bpm (pediatric/neonate

Resolution: 1bpm

Accuracy: ±1 bpm or ±1%, whichever is greater Sensitivity: 0.2mV

 

Data Storage

Trends: A minimum of 120 hours trend data with the resolution no less than 1 minute Events: 200 events

NIBP measurements: 200 events

Interpretation of resting 12-lead ECG results: 20 sets

 

IBP (Optional)

Number of channels: 2

Pressure Range: -50~350mmHg (-6.7~40.0kPa)

Accuracy: ±2% or ±1 mmHg, whichever is greater (excluding sensor error) Resolution: 1 mmHg (0.1kPa)

Refresh Rate: 1s Sensitivity: 5μV/V/mmHg

Zero adjustment range: ±200 mmHg Impedance range: 300~3000Ω

Volume displacement: 0.04mm³/100mmHg

 

EtCO2 (Optional)

Measurement mode: Sidestream, Mainstream Technique: Infrared absorption

Zero RR delay: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s CO2 Range: 0~20.0 vol%

CO2 Accuracy: 0~12 vol%: ± (0.2 vol%+2% of readings) 12~20 vol%: ± (0.2 vol%+6% of readings)

AwRR Measurement Range: 0~150rpm Resolution: 1 rpm

AwRR Accuracy: Mainstream: 0~150rpm, ±1rpm

Sidestream: 0~69rpm, ±1rpm; 70~150rpm, Undefined Alarm limit: EtCO2 High: (EtCO2 Low limit +1mmHg) ~ 150mmHg

EtCO2 Low: 0 ~ (EtCO2 High limit -1mmHg) FiCO2 High: 0 ~ 150mmHg

AwRR High: (AwRR Low limit +1 rpm) ~ 120rpm AwRR Low: 0 ~ (AwRR High limit -1 rpm)

 


Modular Monitor ( 12.1 / 15.6 Inch )


Introduction

The multi-parameter monitor is composed of host, battery, display screen, parameter module, parameter module plug-in box and accessories (pulse saturation probe, body temperature probe, ECG lead, blood pressure cuff, sampling tube). This monitor supports hot plugging for Plug-In Module, where they can be plugged without turning off the monitor.

Standard Para: lead ECG, RESP, SpO2, 2-TEMP, NIBP, PR/HR

Optional Para: 2-IBP, EtCO2, touch screen, recorder, 12-lead ECG, cardiac output, anesthesia depth EEG, CMS

 

Features

-Suitable for adults, children, and newborns.

-12.1/15.6 inches color LCD screen with optional touch screen and rotator knob.

-Upgradable module is interchangeable (plug and play type).

-Capable to visualize 6 or more waveform.

-Support color coding for different waveform.

-28 ST segment analysis with ST trend with continuous display of ST value on screen.

-Multiple screen layout to view big font size in numeric and waveform.

-Trending facilities for up to 360 hours of both graphical & numerical along with event review facility for

 

all parameters and full waveform disclosure facility.

-Different visual alarm with color coding and audible alarms for various parameters with three levels of volume adjustment.

-Support HL7 protocol to access the central workstation

-Energy-saving, low-power design, extending battery life

-Configure noise reduction fan to ensure a quieter and cleaner environment Arrhythmia detection and analysis in various leads.

-5200mAh built-in battery backup of 4 hours

-Dimension: 30cm*15cm*30cm

 

Technical specification

Display

Size:

12.1 inches Color TFT LCD 15.6 inches Color TFT LCD Resolution:

1024*768 pixels 1366*768 pixels

 

ECG

ECG Range: 0.15~5.5mV ECG Resolution: 2.36uV/LSB

HR Range: 15~300bpm (adult) 15~350bpm (child/neonate) HR Accuracy: ±1bpm or ±1% (whichever is greater)

RR Range: 0~120bpm

RR Accuracy: 15~120rpm: ±2rpm or ±2% <15rpm: Undefined

Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s, less than ±5% error

Display sensitivity: 2.5 mm/mV (X0.25), 5 mm/mV (X0.5), 10 mm/mV (X1), 20 mm/mV (X2), 40 mm/mV (X4), Auto, less than ±5% error

 

SpO2

SPO2 Range: 0~100%

SPO2 Accuracy: 70~100%, ±2% <70%, Undefined PI Range: 0~20%

PVI Range: 0.001%

PR Range: 25-250bpm

PR Accuracy: ±2bpm or ±2% (whichever is greater)

 

TEMP

Technique: Thermal resistance Measurement Range: 0~50.0Accuracy: ±0.2°C

Resolution: 0.1°C

 

Refresh Rate: 1s

Alarm limit range: Temp High: (low limit +0.1) ~ 50.0

Temp Low: 0~ (high limit -0.1)

 

NIBP

Technique: Oscillometry

Mode of operation: Manual, Auto, STAT, Sequence Pressure Range: 0~300mmHg

Pressure Accuracy: ±2mmHg or ±1% of reading (whichever is greater) Resolution: 1mmHg

SYS Range:

Adult: 40-270mmHg Pediatric: 40-200mmHg Neonate: 40-135mmHg

DIA Range:

Adult: 10-210mmHg Pediatric: 10-150mmHg Neonate: 10-100mmHg

Mean Range:

Adult: 20-230mmHg Pediatric: 20-165mmHg Neonate: 20-110mmHg

Accuracy: the mean deviation<±5mmHg, the standard deviation<8mmHg

 

Respiration

Technique: Trans-thoracic impedance Lead: Options are lead I and II

Respiration excitation waveform: 300µA RMS, 62.8kHz (±0%) Respiration impedance range: 0.3~5Ω

Baseline impedance range: 200~2500Ω (using an ECG cable with 1kΩ resistance) Bandwidth: 0.2~2Hz (-3 dB)

Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s

 

PR

Measurement range: 25bpm~250bpm Resolution: 1bpm

Accuracy: ±3bpm

Alarm limit: PR High: (PR Low limit +1bpm) ~ 300bpm PR Low: 15bpm ~ (PR High limit -1bpm)

 

HR

Measurement range: 15~300bpm (adult

15~350bpm (pediatric/neonate

 

Resolution: 1bpm

Accuracy: ±1 bpm or ±1%, whichever is greater Sensitivity: 0.2mV

 

Data Storage

Trends:

60 hours trend data with the resolution no less than 1 minute. 4 hours trend data with the resolution no less than 5 second. Events: 100 events

NIBP measurements: 40 events

Interpretation of resting 12-lead ECG results: 25 sets

 

IBP (Optional)

Pressure Range: -50~350mmHg (-6.7kPa40.0kPa)

Accuracy: ±2% or ±1 mmHg, whichever is greater (excluding sensor error) Resolution: 1 mmHg (0.1kPa)

Sensitivity: 5μV/V/mmHg

Zero adjustment range: ±200 mmHg Impedance range: 300~3000Ω

Volume displacement: 0.04mm³/100mmHg

 

CO (Optional)

Range: 0.20~20.00L/Min Accuracy: ±5%

 

ETCO2 (Optional) CO2 Range: 0~20.0vol% CO2 Accuracy:

0~12 vol%: ± (0.2 vol%+2% of reading) 12~20 vol%: ± (0.2 vol%+6% of reading) AwRR Range: 0~150rpm

Resolution: 1 rpm AwRR Accuracy:

Mainstream: 0~150rpm, ±1rpm

Sidestream: 0~69rpm, ±1rpm; 70~150rpm, Undefined


Patient Monitor (8 Inch ) 

Feature

1. 8-inch, two kinds of configuration for choice: 3 Para, or 6 Para 3 Para: NIBP, SPO2, PR

6 Para: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR

2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;

3.     Efficient resistance to interference of defibrillator and electrosurgical cautery;

4.     SPO2 can testing for 0.1% Weak;

5.     RA-LL impedance Respiration;

6.     Trend Coexist Display;

7. OxyCRG DyNamic View Display;

8.     Bed to Bed view Display;

9. Networking capacity and nurse calling system;

10.  Options of Central Monitoring System;

11.  Built-in rechargeable battery 2200mAh;

12.  8" high resolution color TFT LCD display;

13.  Large volume of tabular and graphic trends information storage and easy to recall;

14.  Anti-ESU, anti- defibrillator;

15.  Capture dynamic waveforms.

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL) Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

 

Heart Rate and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great Resolution: 1 bpm

Sensitivity: > 200 (uV P-P) Differential Input Impedance: > 5 MΩ CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV Leakage Current: < 10 uA

Baseline Recovery: < 3 S after Defi. ECG Signal Range: ±8 m V (Vp-p) Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available Review: Available

 

Respiration

Method: Impedance between R-F (RA-LL) Differential Input Impedance: >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 – 2.5 KΩ

 

Bandwidth: 0.3 ~ 2.5 Hz Resp. Measuring Range:

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm Resp. Alarm Range:

-High alarm range limit: 8~120 rpm

-Low alarm range limit: 6~120 rpm Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

 

NIBP

Method: Oscillometric Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm range

Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

-MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: ±8mmHg Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

 

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

 

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm Resolution: 1bpm

Accuracy: ±2bpm

 

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec. Average Time Constant:<10 Sec.

 

Standard Packing List 3 Para

Adult finger SpO2 sensor Adult NIBP cuff

NIBP extension tube AC power adaptor Operation instruction

 

6 Para

5-lead ECG cable (including RESP) Adult finger SpO2 sensor

Adult NIBP cuff NIBP extension tube TEMP sensor

AC power adaptor ECG electrodes Operation instruction

 

Optional Function

Central Monitoring System


Patient Monitor ( 10 Inch ) 

Feature

1.     10.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR

2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;

3.     Efficient resistance to interference of defibrillator and electrosurgical cautery;

4. SPO2 can testing for 0.1% Weak;

5.     RA-LL impedance Respiration;

6. Trend Coexist Display;

7.     OxyCRG DyNamic View Display;

8. Bed to Bed view Display;

9. Networking capacity and nurse calling system;

10.  Options of IBP, EtCO2, Central Monitoring System;

11.  Built-in rechargeable battery 4400mAh;

12.  10.1" high resolution color TFT LCD display;

13.  Large volume of tabular and graphic trends information storage and easy to recall;

14.  Anti-ESU, anti- defibrillator;

15.  Capture dynamic waveforms.

 

 

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL) Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

 

Heart Rate and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great Resolution: 1 bpm

Sensitivity: > 200 (uV P-P) Differential Input Impedance: > 5 MΩ CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV Leakage Current: < 10 uA

Baseline Recovery: < 3 S after Defi. ECG Signal Range: ±8 m V (Vp-p) Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available Review: Available

 

Respiration

Method: Impedance between R-F (RA-LL) Differential Input Impedance: >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 – 2.5 KΩ Bandwidth: 0.3 ~ 2.5 Hz

Resp. Measuring Range:

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm

Resp. Alarm Range:

-High alarm range limit: 8~120 rpm

-Low alarm range limit: 6~120 rpm Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

 

NIBP

Method: Oscillometric Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm range

Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

-MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: ±8mmHg Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

 

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm Resolution: 1bpm

Accuracy: ±2bpm

 

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec. Average Time Constant:<10 Sec.

 

IBP (optional)

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

-ART: 0 ~ 300 mmHg

-PA: -6 ~ 120 mmHg

-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

-P1/P2: -10 ~ 300 mmHg

Press Sensor

Sensitivity: 5 uV/V/mmHg Impedance: 300-3000Ω Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great Actualization interval: about 1 Sec

 

Standard Packing List

5-lead ECG cable (including RESP) Adult finger SpO2 sensor

Adult NIBP cuff NIBP extension tube TEMP sensor

AC power adaptor ECG electrodes Operation instruction

 

Optional Function

IBP, EtCO2, Central Monitoring System


Patient Monitor (12.1 Inch )

Feature

1.     12.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR

2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;

3.     Efficient resistance to interference of defibrillator and electrosurgical cautery;

4. SPO2 can testing for 0.1% Weak;

5.     RA-LL impedance Respiration;

6. Trend Coexist Display;

7.     OxyCRG DyNamic View Display;

8. Bed to Bed view Display;

9.     Networking capacity and nurse calling system;

10.  Options of Internal Recorder, IBP, EtCO2, Central Monitoring System, Touch Screen, VGA, Neonate SPO2

11.  Built-in rechargeable battery 4400mAh;

12.  12.1" high resolution color TFT LCD display;

13.  Large volume of tabular and graphic trends information storage and easy to recall;

14.  Anti-ESU, anti- defibrillator;

15.  Capture dynamic waveforms.

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL) Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

 

Heart Rate and Alarm

Range

-Adult: 15 ~ 300 bpm

-Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great Resolution: 1 bpm

Sensitivity: >200 (uV P-P) Differential Input Impedance: > 5 MΩ CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV Leakage Current: <10uA

Baseline Recovery: < 3S after Defi. ECG Signal Range: ±8 m V (Vp-p) Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available Review: Available

 

Respiration

Method: Impedance between R-F (RA-LL) Differential Input Impedance: >2.5 MΩ Measuring Impedance Range: 0.3 ~ 5.0Ω Base line Impedance Range: 0 ~ 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz Resp. Measuring Range:

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm Resp. Alarm Range:

-High alarm range limit: 8~120 rpm

-Low alarm range limit: 6~120 rpm Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

 

NIBP

Method: Oscillometric Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm range

Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

-MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: ±8mmHg Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

 

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm Resolution: 1bpm

Accuracy: ±2bpm

 

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50°C Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec. Average Time Constant:<10 Sec.

 

IBP (optional)

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

-ART: 0 ~ 300 mmHg

-PA: -6 ~ 120 mmHg

-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

-P1/P2: -10 ~ 300 mmHg

Press Sensor Sensitivity: 5uV/V/mmHg Impedance: 300-3000Ω Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great Actualization interval: about 1 Sec

 

Standard Packing List

5-lead ECG cable (including RESP) Adult finger SpO2 sensor

Adult NIBP cuff NIBP extension tube TEMP sensor

AC power adaptor ECG electrodes Operation instruction

 

Optional Function

Internal Recorder, IBP, EtCO2, Central Monitoring System, Touch Screen, VGA, Neonate SPO2

 


Patient Monitor (15.6 Inch ) 

Feature

1.     15.6-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR

2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;

3.     Efficient resistance to interference of defibrillator and electrosurgical cautery;

4. SPO2 can testing for 0.1% Weak;

5.     RA-LL impedance Respiration;

6. Trend Coexist Display;

7.     OxyCRG DyNamic View Display;

8. Bed to Bed view Display;

9. Networking capacity and nurse calling system;

10.  Options of Internal Recorder, IBP, EtCO2, Central Monitoring System, Neonate SPO2

11.  Built-in rechargeable battery 4800mAh;

12.  15.6" high resolution color TFT LCD display;

13.  Large volume of tabular and graphic trends information storage and easy to recall;

14.  Anti-ESU, anti- defibrillator;

15.  Capture dynamic waveforms.

 

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL) Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

 

Heart Rate and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great Resolution: 1 bpm

Sensitivity: > 200 (uV P-P) Differential Input Impedance: > 5 MΩ CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV Leakage Current: < 10 uA

Baseline Recovery: < 3 S after Defi. ECG Signal Range: ±8 m V (Vp-p) Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available Review: Available

 

Respiration

Method: Impedance between R-F (RA-LL) Differential Input Impedance: >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 – 2.5 KΩ Bandwidth: 0.3 ~ 2.5 Hz

Resp. Measuring Range:

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm Resp. Alarm Range:

-High alarm range limit: 8~120 rpm

-Low alarm range limit: 6~120 rpm Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

 

NIBP

Method: Oscillometric Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm range

Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

-MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: ±8mmHg Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

 

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm Accuracy: ±2bpm

 

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec. Average Time Constant:<10 Sec.

 

IBP (optional)

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

-ART: 0 ~ 300 mmHg

-PA: -6 ~ 120 mmHg

-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

-P1/P2: -10 ~ 300 mmHg

Press Sensor

Sensitivity: 5 uV/V/mmHg Impedance: 300-3000Ω Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great Actualization interval: about 1 Sec

 

Standard Packing List

5-lead ECG cable (including RESP) Adult finger SpO2 sensor

Adult NIBP cuff NIBP extension tube TEMP sensor

AC power adaptor ECG electrodes Operation instruction

 

Optional Function

Internal Recorder, IBP, EtCO2, Central Monitoring System, Neonate SPO2